PLC - CompactLogix 5380 Controllersby Allen Bradley
5069-AEN2TR
Compact 5000 EtherNet/IP Adapter
Compact I/O EtherNet/IP Adapter
Discontinued by the manufacturer — contact us for availability, spares or a recommended replacement.
Specifications
- Depth
- 137mm, 5.39"
- Height
- 138mm, 5.43"
- Isolation
- 300V(cont);No isolation
- ATEX temp code
- T4
- Conducted RF immunity
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz on power and Ethernet ports
- EFT/B immunity
- ±4kV @ 5kHz on power ports, ±2kV @ 5kHz on Ethernet ports
- Emissions
- IEC 61000-6-4
- Enclosure type rating
- None (open-style)
- ESD immunity
- 6 kV contact discharges, 8 kV air discharges
- Insulation stripping length
- 5069-RTB4-SPRING, 5069-RTB6-SPRING connections: 10 mm (0.39 in.), 5069-RTB4-SCREW, 5069-RTB6-SCREW connections: 12 mm (0.47 in.)
- IO link master
- 0
- Isolation voltage
- 250V (continuous), basic insulation type, SA, and MOD power to backplane, 250V (continuous), basic insulation type, SA to MOD power, 250V (continuous), basic insulation type, Ethernet to backplane, 250V (continuous), double insulation type, Ethernet to MO
- MOD power
- 450mA @ 18...32V DC
- MOD Power inrush
- 850 mA for 125 ms
- MOD power passthrough, max
- 9.55A @ 18...32V DC, Maximum level of MOD Power current that the adapter can pass through to the next module in the system
- Module keying
- Electronic keying via progming software
- Nonoperating temperature
- -40 °C
- Number of HW-interfaces industrial Ethernet
- 1
- Operating temperature
- 0 to 60 °C
- Power dissipation, max
- 8.5 W
- Radiated RF immunity
- 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
- Redundancy
- 0
- Relative humidity
- 5...95% noncondensing
- RTB keying
- None
- RTB torque
- 5069-RTB4-SCREW and 5069-RTB6-SCREW only: 0.4 Nm (3.5 in-lb)
- SA power
- 10mA @ 0...32V DC, 25mA @ 0...240V AC, 47...63 Hz, ATEX/IECEx, 125V AC maximum
- SA power passthrough, max
- 9.95A @ 0...32V DC, 9.975A @ 0...240V AC, 47...63 Hz, ATEX/IECEx, 125V AC maximum, Maximum level of SA power current that the adapter can pass through to the next module in the system
- Shock
- Operating: 30 G, Non operating: 50 G
- Supporting protocol for ASI
- 0
- Supporting protocol for AS-Interface Safety at Work
- 0
- Supporting protocol for CAN
- 0
- Supporting protocol for Data-Highway
- 0
- Supporting protocol for DeviceNet
- 0
- Supporting protocol for DeviceNet Safety
- 0
- Supporting protocol for EtherNet/IP
- 1
- Supporting protocol for Foundation Fieldbus
- 0
- Supporting protocol for INTERBUS
- 0
- Supporting protocol for INTERBUS-Safety
- 0
- Supporting protocol for KNX
- 0
- Supporting protocol for LON
- 0
- Supporting protocol for Modbus
- 0
- Supporting protocol for other bus systems
- 0
- Supporting protocol for PROFIBUS
- 0
- Supporting protocol for PROFINET CBA
- 0
- Supporting protocol for PROFINET IO
- 0
- Supporting protocol for PROFIsafe
- 0
- Supporting protocol for SafetyBUS p
- 0
- Supporting protocol for SERCOS
- 0
- Supporting protocol for SUCONET
- 0
- Supporting protocol for TCP/IP
- 0
- Surge transient immunity
- ±1kV line-line (DM) and ±2kV line-earth (CM) on power ports, ±2kV line-earth (CM) on Ethernet ports
- Surrounding air temperature, max
- 60 °C
- Thermal dissipation, max
- 29 btu/h
- Type of data transmission
- Module rack extension
- Vibration
- 5 G @ 10...500 Hz
- Voltage variation
- 10 ms interruption on MOD power port
- Width
- 98 mm
- Wire size
- 5069-RTB4-SPRING, 5069-RTB6-SPRING: 0.5...1.5 mm² (22...16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 2.9 mm (0.11 in.) maximum diam including insulation, single wire connection only, 5069-RTB4-SCREW, 5069-RTB6-SCREW: 0.5
- Wiring category
- 3 - on USB ports, 2 - on power ports, 2 - on Ethernet ports
- With optical interface
- 0
- With potential separation
- 0
- Bulletin
- 5069
- Series
- A
- Lifecycle Status
- Discontinued
Request a Quote
Need pricing, availability or more details? We'll get back to you.
Datasheet
Datasheet not available yet — request it from our team.