HMI PanelView Plus 6 400by Allen Bradley
2711P-T12C4A9
PanelView Plus Terminal
2711 PanelView Plus 6 Terminal, 1250 Model, Touch Screen, Color, Standard Communication - Ethernet & RS-232, AC Input, Windows CE 6.0 with Extended Features
Discontinued by the manufacturer — contact us for availability, spares or a recommended replacement.
Specifications
- Model
- 1250 Model
- Operator Input
- Touch Screen
- Display
- Color
- Communication
- Standard Communication - Ethernet & RS-232
- Power
- AC Input
- Operating System
- Windows CE 6.0 with Extended Features
- Additional software components, loadable
- 1
- Altitude, operating
- 2000 m
- Backlight
- CCFL, 50000 hr minimum at 25 ° C (77 °F) field replaceable
- Battery life
- 4 yr minimum at 25 °C (77 °F)
- Battery (real-time clock)
- Battery-backed clock timestA critical data, accuracy is ±2 min per month
- Battery replacement
- Field-replaceable: cat. no. 2711P-RY2032 or equivalent CR2032 coin-cell lithium battery
- Built-in depth
- 55 mm
- Communication ports
- Ethernet (10/100 Mbps, Auto-MDI/MDI-X), RS-232, (2) USB host, Network interface for optional Ethernet, DH+/DH-485, or ControlNet (scheduled or unscheduled) communication module
- Cutout dimensions
- 257 x 338 mm
- Degree of protection (IP), front side
- IP65
- Degree of protection (NEMA), front side
- 4X
- Description
- PanelView Plus 6 - 700 to 1500 terminals with extended features
- Display area
- 246 x 184 mm
- Display size
- 12.1 in
- Display type
- Color active-matrix TFT
- Enclosure rating
- NEMA/UL Type 12, 13, 4X (indoor use only), and IEC IP54, IP65
- External storage
- Secure Digital (SD) card, cat. no.1784-SDx, supported by hot-swappable SD card slot, USB flash drive that is supported by high-speed, hot-swappable, 2.0 USB host port
- Heat dissipation
- 240 btu/hr
- Height of the front
- 282 mm
- IO link master
- 0
- List of degrees of protection (IP)
- IP54, IP65
- List of degrees of protection (NEMA)
- 12, 13, 4X
- Luminance
- 300 cd/m2 (Nits)
- Memory
- 512 MB RAM, 512 MB nonvolatile memory, (approx. 79 MB free user memory)
- Nonoperating temperature
- -25 °C
- Number of HW-interfaces industrial Ethernet
- 1
- Number of HW-interfaces RS-232
- 1
- Number of HW-interfaces RS-422
- 1
- Number of HW-interfaces USB
- 2
- Number of online languages
- 20
- Number of password levels
- 2
- Number of pixels, horizontal
- 800
- Number of pixels, vertical
- 600
- Operating temperature
- 0 °C
- Power consumption
- 160VA max, 65VA typical
- Process default value (input) possible
- 0
- Process value representation (output) possible
- 0
- Radio standard Bluetooth
- 0
- Radio standard GPRS
- 0
- Radio standard GSM
- 0
- Radio standard UMTS
- 0
- Radio standard Wi-Fi 802.11
- 0
- Rail mounting possible
- 0
- Recommended external power supply
- Cat. No. 1606-XLE120E, safety extra low voltage (SELV) or protected extra-low voltage (PELV) power supply for 100...240V AC @ 250VA max
- Relative humidity
- 5...95% noncondensing
- Screen diagonal
- 12.1 in
- Shock
- Operating: 15 G at 11 ms
- Software
- FactoryTalk View Machine Edition software, version 6.0 or later, FactoryTalk ViewPoint software, version 1.2 or later
- Suitable for safety functions
- 0
- Supply voltage AC 50 Hz
- 100 V
- Supply voltage AC 60 Hz
- 100 V
- Supporting protocol for ASI
- 0
- Supporting protocol for AS-Interface Safety at Work
- 0
- Supporting protocol for CAN
- 0
- Supporting protocol for Data-Highway
- 0
- Supporting protocol for DeviceNet
- 0
- Supporting protocol for DeviceNet Safety
- 0
- Supporting protocol for EtherNet/IP
- 0
- Supporting protocol for Foundation Fieldbus
- 0
- Supporting protocol for INTERBUS
- 0
- Supporting protocol for INTERBUS-Safety
- 0
- Supporting protocol for KNX
- 0
- Supporting protocol for LON
- 0
- Supporting protocol for Modbus
- 0
- Supporting protocol for other bus systems
- 0
- Supporting protocol for PROFIBUS
- 0
- Supporting protocol for PROFINET CBA
- 0
- Supporting protocol for PROFINET IO
- 0
- Supporting protocol for PROFIsafe
- 0
- Supporting protocol for SafetyBUS p
- 0
- Supporting protocol for SERCOS
- 0
- Supporting protocol for SUCONET
- 0
- Supporting protocol for TCP/IP
- 0
- Touch screen, actuation
- 1 mon presses
- Touch screen
- 8-wire analog resistive
- Touch screen, operating force
- 10 g
- Touch technology
- Resistive touch
- Type of display
- TFT
- Useful project memory/user memory
- 79000 mb
- Vibration
- 10...57 Hz, 0.012 peak-to-peak displacement, 57...500 Hz, 2 G peak acceleration
- Voltage type of supply voltage
- AC
- Wall mounting/direct mounting
- 1
- Weight, approx
- 3.2 g
- Width of the front
- 363 mm
- With alpha numeric keyboard
- 0
- With colour display
- 1
- With message indication
- 1
- With message system (incl. buffer and confirmation)
- 1
- With numeric keyboard
- 0
- With printer output
- 1
- With recipes
- 0
- With SW interfaces
- 1
- Bulletin
- 2711P
- Series
- A
- Lifecycle Status
- Discontinued
Request a Quote