HMI PanelView Plus 6 400by Allen Bradley
2711P-RSACDIN
PanelView Plus AC to DC 3A Power Supply
DIN-rail Mount AC-to-DC Power Supply, 85...265VAC, 47...63 Hz, for PanelView Component, PanelView Plus 700-1500, and PanelView Plus CE terminals
Discontinued by the manufacturer — contact us for availability, spares or a recommended replacement.
Specifications
- Power
- 85...265VAC
- Features
- 47...63 Hz, for PanelView Component, PanelView Plus 700-1500, and PanelView Plus CE terminals
- Class
- Power supply units
- Output Amperage
- 3 A
- Power Supply
- DIN-rail Mt AC-to-DC Power
- Conducted RF immunity
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
- Depth
- 69 mm
- Description
- DIN rail power supply, AC-to-DC, 85...265V AC @ 47...63Hz
- Direct mounting possible
- 0
- EFT/B immunity
- ±2kV @ 5kHz on power ports
- Emissions
- CISPR 11, Group 1, class A (with appropriate enclosure)
- Enclosure type rating
- None (open-style)
- ESD immunity
- 4 kV contact discharges, 8 kV air discharges
- Height
- 87 mm
- Inrush current
- 40 A typical, 1 AC cycle @ Vin 265V AC @ 55°C
- Interruption
- Output voltage will stay within specification when input drops out for 0.5 cycle @ 47 Hz, 85V AC with maximum load
- Isolation voltage
- 2830V DC @ 1s
- Leakage current
- 0.5 mA rms maximum @ rated input and output
- Minimum load
- 50 mA
- Nominal supply voltage
- 120V AC @ 47...63Hz, 1.7 A maximum, 230V AC @ 47...63Hz, 1.1 A maximum
- Nominal value output voltage 1
- 24 V
- Operating temperature
- 0 °C
- Output current
- 3 A maximum horizontal mount
- Output voltage range
- 20.4...27.6V DC (includes noise and 5% AC ripple)
- Overcurrent protection
- Current limit 3.2 A minimum (107% minimum)
- Overvoltage protection
- Output internally limited to 35V DC cycle power to re-energize
- Power conductor
- Wire size: 12 gauge (4 mm²) maximum solid or stranded copper wire rated at 75 °C or greater, 1.2 mm (3/64 in.) insulation maximum Category: 1
- Radiated RF immunity
- 10V/m with 1 kHz sine-wave 80% AM from 30...1000 MHz
- Rail mounting possible
- 1
- Rated supply voltage at AC 50 Hz
- 85 V
- Rated supply voltage at AC 60 Hz
- 85 V
- Relative humidity
- 5...95% noncondensing
- Shock
- Operating: 30 G
- Stabilized
- 1
- Storage temperature
- -40 °C
- Suitable for safety functions
- 1
- Surge transient immunity
- ±1 kV line-line (DM) and ±2 kV line-earth (CM) on ac power ports
- Terminal screw torque
- 0.5 nm
- Vibration
- 5 G @ 10...500 Hz
- Voltage type of supply voltage
- AC
- Wall mounting possible
- 1
- Width
- 68 mm
- Bulletin
- 2711P
- Series
- A
- Lifecycle Status
- Discontinued
Request a Quote