PLC - Micro800 Plug-in Modulesby Allen Bradley
2080-SERIALISOL
Micro800 Isolated Serial Port Plug-In
Micro800 System, RS232/485 isolated serial port
Specifications
- Communication
- RS232/485 isolated serial port
- Temperature Rating
- -20…65 °C (-4…149 °F)
- Cable length using RS485, Max
- 1000
- Conducted RF immunity
- IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
- Data transmission type
- Serial
- EFT/B immunity
- IEC 61000-4-4: ± 2kV @ 5kHz on communication ports
- Emissions
- CISPR 11 (IEC 61000-6-4): Class A
- ESD immunity
- IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
- IO link master
- 0
- Isolated voltage
- 500V AC
- Mounting torque
- 0.2 nm
- Nonoperating temperature
- -40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
- Operating temperature
- -20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
- Radiated RF immunity
- IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
- Redundancy
- 0
- Shock
- Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock)
- SIL according to IEC 61508
- None
- Suitable for safety functions
- 0
- Supporting protocol
- Modbus RTU (RS232 and RS485)
- Supporting protocol for ASI
- 0
- Supporting protocol for AS-Interface Safety at Work
- 0
- Supporting protocol for CAN
- 0
- Supporting protocol for Data-Highway
- 0
- Supporting protocol for DeviceNet
- 1
- Supporting protocol for DeviceNet Safety
- 1
- Supporting protocol for EtherNet/IP
- 0
- Supporting protocol for Foundation Fieldbus
- 0
- Supporting protocol for INTERBUS
- 0
- Supporting protocol for INTERBUS-Safety
- 0
- Supporting protocol for KNX
- 0
- Supporting protocol for LON
- 0
- Supporting protocol for Modbus
- 0
- Supporting protocol for other bus systems
- 0
- Supporting protocol for PROFIBUS
- 0
- Supporting protocol for PROFINET CBA
- 0
- Supporting protocol for PROFINET IO
- 0
- Supporting protocol for PROFIsafe
- 0
- Supporting protocol for SafetyBUS p
- 0
- Supporting protocol for SERCOS
- 0
- Supporting protocol for SUCONET
- 0
- Supporting protocol for TCP/IP
- 0
- Surge transient immunity
- IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports
- Surrounding air temperature, max
- 65 °C
- Terminal screw torque
- 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
- Transmission rate
- 19.2 kbps
- Vibration
- IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
- Wire size
- 0.14...1.5 mm² (26...16 AWG) solid copper wire or, 0.14...1.0 mm² (22...18 AWG) stranded copper wire, Rated at 90 °C (194 °F) insulation max
- With optical interface
- 0
- With potential separation
- 0
- Bulletin
- 2080
- Series
- A
- Lifecycle Status
- Active
Request a Quote