2080-OF2

Micro800 2 Point Analog Output Plug-In

Micro800 System, 2-ch V/I Analog Output Unipolar 0-10V/0-20mA (non-isolated)

Specifications

Features
2-ch V/I Analog Output Unipolar 0-10V/0-20mA (non-isolated)
I/O Isolation
None
I/O Status Indication
None
Temperature Rating
-20…65 °C (-4…149 °F)
Analogue inputs configurable
0
Analogue outputs configurable
1
Capacitive load, max
0.1 µF @ voltage outputs
Channel to channel isolation
Non-isolation
Conducted RF immunity
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Current load on voltage output, max
10 mA
Current range
0 mA
D/A Conversion rate (all channels), max
2.5 ms
EFT/B immunity
IEC 61000-4-4: ±2kV @ 5kHz on shielded ports
Emissions
CISPR 11 (IEC 61000-6-4): Class A
ESD immunity
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
Inductive load, max
0.01 mH @ current outputs
Input, current
0
Input group to bus isolation
Non-isolation
Input, resistance thermometer
0
Input, resistor
0
Input signal, configurable
0
Input, thermocouple
0
Input, voltage
0
Load range on voltage output
> 1k Ω @ 10V DC
Mounting torque
0.2 nm
Non-linearity
±0.1% @ in % full scale
Nonoperating temperature
-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
North American temperature code
T4
Number of analogue outputs
2
Open and short-circuit protection
1
Operating altitude
2000 m
Operating temperature
-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Output count range
0 to 65535
Output, current
1
Output error
Voltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F)
Output overvoltage protection
1
Output signal configurable
1
Output, voltage
1
Overall accuracy
Voltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C
Power consumption
<60mA @ 24V
Radiated RF immunity
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
Recommended maximum shielded cable length
10 m
Relative humidity
IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing
Repeatability
±0.1% @ in % full scale
Resistive load on current output
0...500 Ω (includes wire resistance)
Resolution of the analogue outputs
12 bit
Shock
IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating
SIL according to IEC 61508
None
Step response to 63%
5 ms
Suitable for safety functions
0
Surge transient immunity
IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports
Surrounding air temperature, max
65 °C
Terminal screw torque
0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
Type of electric connection
Screw connection
Vibration
IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
Voltage ranges
0
Wire size
Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum