PLC - Micro800 Plug-in Modulesby Allen Bradley
2080-IF2
Micro800 2 Point Analog Input Plug-In
Micro800 System, 2-ch V/I Analog Input Unipolar 0-10V/0-20mA (non-isolated)
Specifications
- Features
- 2-ch V/I Analog Input Unipolar 0-10V/0-20mA (non-isolated)
- Consist Of
- Screws
- I/O Isolation
- None
- Analogue inputs configurable
- 1
- Analogue outputs configurable
- 0
- Channel to channel isolation
- Non-isolation
- Conducted RF immunity
- IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
- Current range
- 0 mA
- Data range
- 0 to 65535
- EFT/B immunity
- IEC 61000-4-4: ±2kV @ 5kHz on shielded ports
- Emissions
- CISPR 11 (IEC 61000-6-4): Class A
- ESD immunity
- IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
- Field input calibration
- Not required
- Input, current
- 1
- Input group to bus isolation
- No isolation
- Input impedance
- >100 kΩ for voltage mode, 250 Ω for current mode
- Input, resistance thermometer
- 0
- Input, resistor
- 0
- Input signal, configurable
- 0
- Input, thermocouple
- 0
- Input, voltage
- 1
- Module error
- Voltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F)
- Mounting torque
- 0.2 nm
- Non-linearity
- ±0.1% @ in % full scale
- Nonoperating temperature
- -40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
- North American temperature code
- T4
- Number of analogue inputs
- 2
- Operating altitude
- 2000 m
- Operating temperature
- -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
- Output, current
- 0
- Output signal configurable
- 0
- Output, voltage
- 0
- Overall accuracy
- Voltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C
- Power consumption
- <60mA @ 3.3V
- Radiated RF immunity
- IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
- Recommended maximum shielded cable length
- 10 m
- Relative humidity
- IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing
- Repeatability
- ±0.1%
- Resolution of the analogue inputs
- 12 bit
- Shock
- IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating
- SIL according to IEC 61508
- None
- Suitable for safety functions
- 0
- Surge transient immunity
- IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports
- Surrounding air temperature, max
- 65 °C
- Terminal screw torque
- 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
- Type of electric connection
- Screw connection
- Update time
- 180 ms per enabled channel
- Vibration
- IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
- Voltage ranges
- 0
- Wire size
- Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum
- Bulletin
- 2080
- Series
- A
- Lifecycle Status
- Active