Specifications

Communication
DeviceNet Scanner, Supports upto 20 Nodes
Communication Protocol
DeviceNet
Power Supply
24V DC
Temperature Rating
-20…65 °C (-4…149 °F)
Backplane power consumption
50mA @ 24V DC
Conducted RF immunity
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Data transmission type
DeviceNet
Depth
20 mm
DeviceNet communication rate, max
125 Kbps - 420 m (1378 ft.), 250 Kbps - 200 m (656 ft.), 500 Kbps - 75 m (246 ft.)
DeviceNet current
24V DC @ 300mA Class 2
DeviceNet status indicators
Module status - red/green Network status - red/green
EFT/B immunity
IEC 61000-4-4: ± 2kV @ 5kHz on communication ports
Emissions
CISPR 11 (IEC 61000-6-4): Class A
Enclosure type rating
Meets IP20
ESD immunity
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
Height
62 mm
IO link master
0
Isolation voltage
50V (continuous), Type tested for 60 s @ 500V AC
Network protocol
I/O Slave messaging: poll command
Nonoperating temperature
-40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Number of nodes, max
20 nodes for I/O ops
Operating temperature
-20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Power dissipation, max
1.44 W
Preferred power supply
1606-XLSDNET4
Radiated RF immunity
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
Redundancy
0
Relative humidity
IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing
Shock
Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock)
SIL according to IEC 61508
None
Suitable for safety functions
0
Supporting protocol for ASI
0
Supporting protocol for AS-Interface Safety at Work
0
Supporting protocol for CAN
0
Supporting protocol for Data-Highway
0
Supporting protocol for DeviceNet
1
Supporting protocol for DeviceNet Safety
0
Supporting protocol for EtherNet/IP
0
Supporting protocol for Foundation Fieldbus
0
Supporting protocol for INTERBUS
0
Supporting protocol for INTERBUS-Safety
0
Supporting protocol for KNX
0
Supporting protocol for LON
0
Supporting protocol for Modbus
0
Supporting protocol for other bus systems
0
Supporting protocol for PROFIBUS
0
Supporting protocol for PROFINET CBA
0
Supporting protocol for PROFINET IO
0
Supporting protocol for PROFIsafe
0
Supporting protocol for SafetyBUS p
0
Supporting protocol for SERCOS
0
Supporting protocol for SUCONET
0
Supporting protocol for TCP/IP
0
Surge transient immunity
IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports
Surrounding air temperature, max
65 °C
Vibration
IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
Weight
35 g
Width
31.5 mm
Wire category
1 - on power ports
Wire size
0.25...2.5 mm2 (24...14 AWG) solid copper wire, 0.25...2.5 mm2 (24...14 AWG) stranded copper wire, Rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation maximum
With optical interface
0
With potential separation
0
Bulletin
2080
Series
A
Lifecycle Status
Active

Request a Quote

Need pricing, availability or more details? We'll get back to you.

* Required. Please give an email or a phone number.

Prefer WhatsApp? Message us directly