PLC - Micro800 Plug-in Modulesby Allen Bradley
2080-DNET20
Micro800 DeviceNet Scanner Plug-In
Micro800 System, DeviceNet Scanner, Supports upto 20 Nodes
Specifications
- Communication
- DeviceNet Scanner, Supports upto 20 Nodes
- Communication Protocol
- DeviceNet
- Power Supply
- 24V DC
- Temperature Rating
- -20…65 °C (-4…149 °F)
- Backplane power consumption
- 50mA @ 24V DC
- Conducted RF immunity
- IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
- Data transmission type
- DeviceNet
- Depth
- 20 mm
- DeviceNet communication rate, max
- 125 Kbps - 420 m (1378 ft.), 250 Kbps - 200 m (656 ft.), 500 Kbps - 75 m (246 ft.)
- DeviceNet current
- 24V DC @ 300mA Class 2
- DeviceNet status indicators
- Module status - red/green Network status - red/green
- EFT/B immunity
- IEC 61000-4-4: ± 2kV @ 5kHz on communication ports
- Emissions
- CISPR 11 (IEC 61000-6-4): Class A
- Enclosure type rating
- Meets IP20
- ESD immunity
- IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
- Height
- 62 mm
- IO link master
- 0
- Isolation voltage
- 50V (continuous), Type tested for 60 s @ 500V AC
- Network protocol
- I/O Slave messaging: poll command
- Nonoperating temperature
- -40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
- Number of nodes, max
- 20 nodes for I/O ops
- Operating temperature
- -20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
- Power dissipation, max
- 1.44 W
- Preferred power supply
- 1606-XLSDNET4
- Radiated RF immunity
- IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
- Redundancy
- 0
- Relative humidity
- IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing
- Shock
- Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock)
- SIL according to IEC 61508
- None
- Suitable for safety functions
- 0
- Supporting protocol for ASI
- 0
- Supporting protocol for AS-Interface Safety at Work
- 0
- Supporting protocol for CAN
- 0
- Supporting protocol for Data-Highway
- 0
- Supporting protocol for DeviceNet
- 1
- Supporting protocol for DeviceNet Safety
- 0
- Supporting protocol for EtherNet/IP
- 0
- Supporting protocol for Foundation Fieldbus
- 0
- Supporting protocol for INTERBUS
- 0
- Supporting protocol for INTERBUS-Safety
- 0
- Supporting protocol for KNX
- 0
- Supporting protocol for LON
- 0
- Supporting protocol for Modbus
- 0
- Supporting protocol for other bus systems
- 0
- Supporting protocol for PROFIBUS
- 0
- Supporting protocol for PROFINET CBA
- 0
- Supporting protocol for PROFINET IO
- 0
- Supporting protocol for PROFIsafe
- 0
- Supporting protocol for SafetyBUS p
- 0
- Supporting protocol for SERCOS
- 0
- Supporting protocol for SUCONET
- 0
- Supporting protocol for TCP/IP
- 0
- Surge transient immunity
- IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports
- Surrounding air temperature, max
- 65 °C
- Vibration
- IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
- Weight
- 35 g
- Width
- 31.5 mm
- Wire category
- 1 - on power ports
- Wire size
- 0.25...2.5 mm2 (24...14 AWG) solid copper wire, 0.25...2.5 mm2 (24...14 AWG) stranded copper wire, Rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation maximum
- With optical interface
- 0
- With potential separation
- 0
- Bulletin
- 2080
- Series
- A
- Lifecycle Status
- Active
Request a Quote