Specifications

Features
4 Channel Analog Output Module
analog output modules
4 Channel Analog Output Module
Class
Progmable Logic Controller
Current Range
4-20
Depth
87
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
analog output
Number Of Channels
4 point
Output
4 Point, ±10V, 4-20 mA
Temperature Rating
-20…65 °C (-4…149 °F)
Analog normal operating range
Voltage: 0...10V DC
Analogue inputs configurable
0
Analogue outputs configurable
1
Bus current draw, max
40mA @ 5V DC, 165mA @ 24V DC
Conducted immunity
10V @ 0.15...80MHz
D/A converter type
R-2R ladder voltage switching
ESD immunity
EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect
Fast transient burst
IEC1000-4-4: 2kV @ 5kHz
Full scale analog ranges
Voltage: 0...10.5V DC, Current: 0...21 mA
Hazardous environment class
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Input and output group to system isolation
30V AC/30V DC rated working voltage (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min
Input, current
1
Input, resistance thermometer
0
Input, resistor
0
Input signal, configurable
1
Input, thermocouple
0
Input, voltage
1
Load range on voltage output
>1KΩ
Module power LED
On: indicates power is applied
Non-linearity
< ±0.59% (in % full scale)
Number of outputs
4 single-ended (unipolar)
Open and short-circuit protection
Continuous
Operating altitude
2000 m
Operating humidity
5...95% noncondensing
Operating temperature
-20 °C
Output, current
1
Output protection
-32 mA
Output ripple range
<±0.1% @ 0...500Hz (referred to output range)
Output signal configurable
1
Output update time
Typical: 2.5 ms
Output, voltage
1
Radiated and conducted emissions
EN50081-2: Class A
Radiated immunity
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Reactive load, current output
<0.1 mH
Reactive load, voltage output
<1 µF
Recommended cable
Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.)
Repeatability
-0.12 to 0.12%
Resistive load on current output
0...500 Ω (includes wire resistance)
Resolution of the analogue outputs
12 bit
Shock
Operating: 30 g
Storage temperature
-40 °C
Suitable for safety functions
0
Surge immunity
IEC1000-4-5: 1kV galvanic gun
Type of electric connection
Screw connection
Typical overall accuracy
±1.17% full scale @ -20...65 °C (Only applicable to Series B I/O modules.)
Vibration
Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak
Weight
Shipping: 235 g (0.517 lbs.) approximately (with cartoon)
Width
40 mm
Bulletin
1762
Series
B
Lifecycle Status
Active Mature

Request a Quote

Need pricing, availability or more details? We'll get back to you.

* Required. Please give an email or a phone number.

Prefer WhatsApp? Message us directly

Datasheet

Datasheet not available yet — request it from our team.