Skip to content
PLC - MicroLogix 1200 Controllersby Allen Bradley

1762-OB8

MicroLogix 8 Point Digital Output Module

MicroLogix 1200 System, 8 Point 24 VDC Source Output Module

Specifications

Power
8 Point 24 VDC Source Output Module
Class
Progmable Logic Controller
Depth
87
digital output modules
8 Point 24V DC Source Output Module
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
digital
Number Of Channels
8 Point
Output
8 Point, 24V DC Source
Temperature Rating
0…55 °C (32…131 °F)
Altitude
2000 m
Bus current draw, max
115mA @ 5V DC (0.575 W)
Conducted RF immunity
IEC 1000-4-6: 10V @ 0.15...80MHz
Continuous current per common, max
8A @ 30°C (86 °F)
Continuous current per module, max
8A @ 30°C (86 °F)
Continuous current per point, max
1A @ 30°C (86 °F)
Digital inputs configurable
0
Digital outputs configurable
0
EFT/B immunity
IEC1000-4-4: 2kV @ 5kHz
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Hazardous environment class
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Heat dissipation, max
1.61 W
Isolated groups
Group 1: Outputs 0...7
Number of digital outputs
8
Off-state leakage current, max
1 mA
On-state current, min
1 mA
On-state voltage drop, max
1.0V DC
Operating humidity
5...95% noncondensing
Operating temperature
-20 to 65 °C
Operating voltage
20.4...26.4V DC
Output group to backplane isolation
Verified by one of the following dielectric tests: 1200V AC @ 1s or 1697V DC @ 1s 75V DC working voltage (IEC Class 2 reinforced insulation)
Power supply distance rating
6 (The module may not be more than 6 modules away from the power supply.)
Radiated and conducted emissions
EN50081-2: Class A
Radiated RF immunity
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Redundancy
0
Shock
Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G
Short-circuit protection, outputs available
0
Signal delay, resistive load
On delay: 0.1 ms Off delay: 1.0ms
Storage temperature, min
-40 °C
Suitable for safety functions
0
Surge current, max
2.0 A (Repeatability is once every 2 s at 55 °C (131 °F), once every s at 30 °C (86 °F) for a duration of 10 ms.)
Surge transient immunity
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
Type of digital output
Relay
Type of electric connection
Screw connection
Type of output voltage
DC
Vibration
Operating: 10…500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G
Voltage category
24V DC
Weight
210 g
Width
40.4 mm
Bulletin
1762
Series
A
Lifecycle Status
Active Mature

Request a Quote

Need pricing, availability or more details? We'll get back to you.

* Required. Please give an email or a phone number.

Prefer WhatsApp? Message us directly

Datasheet

Datasheet not available yet — request it from our team.