PLC - MicroLogix 1200 Controllersby Allen Bradley
1762-OA8
MicroLogix 8 Point Digital Output Module
MicroLogix 1200 System, 8 Point 120/240 VAC Output Module
Specifications
- Power
- 8 Point 120/240 VAC Output Module
- Class
- Progmable Logic Controller
- Depth
- 87
- digital output modules
- 8 Point 120/240V AC Output Module
- Height
- 90
- I/O Isolation
- Isolated
- I/O Status Indication
- LED
- Module Interfaces
- digital
- Number Of Channels
- 8 Point
- Output
- 8 Point , 120/240V AC Triac
- Temperature Rating
- 0…55 °C (32…131 °F)
- Altitude
- 2000 m
- Bus current draw, max
- 115mA @ 5V DC (0.575 W)
- Conducted RF immunity
- IEC 1000-4-6: 10V @ 0.15...80MHz
- Continuous current per common, max
- 2.0A @ 30°C (86 °F)
- Continuous current per module, max
- 4A @ 30°C (86 °F)
- Continuous current per point, max
- 0.5A @ 30°C (86 °F)
- Digital inputs configurable
- 0
- Digital outputs configurable
- 0
- EFT/B immunity
- IEC1000-4-4: 2kV @ 5kHz
- ESD immunity
- IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
- Hazardous environment class
- Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
- Heat dissipation, max
- 2.9 W
- Isolated groups
- Group 1: Outputs 0..3, Group 2: Outputs 4...7
- Number of digital outputs
- 8
- Off-state leakage current, max
- 2.5mA @ 265V
- On-state current, min
- 10 mA
- On-state voltage drop, max
- 0.5A @ 1.5V
- Operating humidity
- 5...95% noncondensing
- Operating temperature
- -20 to 65 °C
- Operating voltage
- 85...265V AC @ 47...63Hz
- Output group to backplane isolation
- Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation)
- Output group to output group isolation
- Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation)
- Power supply distance rating
- 6 (The module may not be more than 6 modules away from the power supply.)
- Radiated and conducted emissions
- EN50081-2: Class A
- Radiated RF immunity
- IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
- Redundancy
- 0
- Shock
- Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G
- Short-circuit protection, outputs available
- 0
- Signal delay, resistive load
- On delay: 0.5 cycle Off delay: 0.5 cycle
- Storage temperature, min
- -40 °C
- Suitable for safety functions
- 0
- Surge current, max
- 5.0 A (Repeatability is once every 2 s for a duration of 25 ms.)
- Surge transient immunity
- IEC1000-4-5: 2 kV common mode, 1 kV differential mode
- Type of digital output
- Relay
- Type of electric connection
- Screw connection
- Type of output voltage
- AC
- Vibration
- Operating: 10…500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G
- Voltage category
- 100...240V AC
- Weight
- 215 g
- Width
- 40.4 mm
- Bulletin
- 1762
- Series
- A
- Lifecycle Status
- Active Mature
Request a Quote
Need pricing, availability or more details? We'll get back to you.
Datasheet
Datasheet not available yet — request it from our team.