Skip to content
PLC - MicroLogix 1200 Controllersby Allen Bradley

1762-IR4

MicroLogix 4 Point Module

MicroLogix 1200 System, MicroLogix 4 Point Module

Specifications

Features
MicroLogix 4 Point Module
Class
Progmable Logic Controller
Depth
87
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
resistance thermom
Number Of Channels
4 point
Temperature Rating
0…55 °C (32…131 °F)
Thermocouple Type
4 Channel, RTD/Resistance Module
Accuracy drift
At 0...55 °C ±0.026 °C/°C (0.026 °F/°F) for Pt 385, ±0.007 Ω/°C (0.012 Ω/°F) for 150 Ω range, ±0.023 °C/°C (0.023 °F/°F) for Pt 3916, ±0.023 Ω/°C (0.041 Ω/°F) for 500 Ω range, ±0.012 °C/°C (0.012 °F/°F) for Ni, ±0.043 Ω/°C (0.077 Ω/°F) for 1,000 Ω range,
A/D converter type
Delta-Sigma
Analogue inputs configurable
0
Analogue outputs configurable
0
Bus current draw
50mA @ 24V DC, maximum
Cable impedance
Maximum @ 25 Ω (operating with >25 Ω will reduce accuracy)
Calibration
The module performs autocalibration on channel enable and on a configuration change between channels. You can also prog the module to calibrate every five minutes
Channel diagnostics
Over or under range or open circuit condition by bit reporting for analog inputs
Channel to channel isolation
±10V DC
Common mode rejection
>110 dB at 60 Hz (with 10 or 60 Hz filter)
Conducted immunity
IEC 1000-4-6: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Excitation current source
0.5 mA and 1.0 mA selectable per channel
Fast transient burst
IEC1000-4-4: 2kV @ 5kHz
Hazardous environment class
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Heat dissipation
1.5 total W (the W per point, plus the minimum W, with all points enabled)
Input and output group to system isolation
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
Input channel configuration
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
Input, current
0
Input impedance
>10 MΩ
Input, resistance thermometer
0
Input, resistor
1
Input signal, configurable
1
Input, thermocouple
0
Input type
604 Ω Nickel-Iron 518
Input, voltage
0
Module power LED
ON: indicates power is applied
Non-linearity
±0.05% (in % full scale)
Normal mode rejection ratio
70 dB minimum @ 60 Hz with the 10 or 60 Hz filter selected
Number of analogue inputs
4
Open-circuit detection time
6 ms
Operating altitude
2000 m
Operating humidity
5...95% noncondensing
Operating temperature
-20 °C
Output, current
0
Output signal configurable
0
Output, voltage
0
Overload at input terminals
Maximum @ ±35V DC continuous
Power supply distance rating
6 (the module may not be more than 6 modules away from the system power supply)
Radiated and conducted emissions
EN50081-2: Class A
Radiated immunity
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Recommended cable
Belden 8761 (shielded)
Repeatability
±0.2 Ω for other resistances
Resolution
Input filter and configuration dependent
Shipping weight, approx
260 g
Shock
Operating: 30 G
Storage temperature
-40 °C
Suitable for safety functions
0
Surge immunity
IEC1000-4-5: 1kV galvanic gun
Type of electric connection
Screw connection
Typical accuracy
At 25 ° C (77 °F) ambient with module operating temperature at 25 °C (77 °F)
Typical overall accuracy
±0.5 °C (°F) for Pt 385
Update time
Input filter and configuration dependent (typical)
Vibration
Operating: 10...500 Hz, 5 G, 0.030 in @ maximum peak-to-peak
Width
40 mm
Bulletin
1762
Series
A
Lifecycle Status
Active Mature

Request a Quote

Need pricing, availability or more details? We'll get back to you.

* Required. Please give an email or a phone number.

Prefer WhatsApp? Message us directly

Datasheet