PLC - MicroLogix 1200 Controllersby Allen Bradley

1762-IA8

MicroLogix 8 Point Digital Input Module

MicroLogix 1200 System, 8 Point 120 VAC Input Module

Specifications

Power
8 Point 120 VAC Input Module
Class
Progmable Logic Controller
Depth
87
digital input modules
8 Point 120V AC Input Module
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
digital
Number Of Channels
8 Point
Temperature Rating
0…55 °C (32…131 °F)
Altitude
2000 m
Bus current draw, max
50mA @ 5V DC (0.25 W)
Conducted RF immunity
IEC 1000-4-6: 10V @ 0.15...80MHz
Digital inputs configurable
0
Digital outputs configurable
0
EFT/B immunity
IEC1000-4-4: 2kV @ 5kHz
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Hazardous environment class
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Heat dissipation, max
2 W
IEC input compatibility
Type 1+
Input group to backplane isolation
Verified by one of the following dielectric tests: 1517V AC @ 1s or 2145V DC @ 1s. 132V AC working voltage (IEC Class 2 reinforced insulation)
Inrush current, max
250 mA
Isolated groups
Group 1: inputs 0...7 (internally connected commons)
Nominal Impedance
12 kΩ @ 50 Hz
Number of commons
1
Number of digital inputs
8
Off-state current, max
2.5 mA
Off-state voltage, max
20V AC
ON-state current, max
16.0mA @ 132V AC, 63 Hz
On-state current, min
5.0mA @ 79V AC, 47 Hz
On-state current, nom
12.0mA @ 120V AC, 60 Hz
On-state voltage, min
79V...132V AC
Operating humidity
5...95% noncondensing
Operating temperature
-20 to 65 °C
Operating voltage
79...132V AC @ 47...63Hz
Power supply distance rating
6 (the module may not be more than 6 modules away from the system power supply)
Radiated and conducted emissions
EN50081-2: Class A
Radiated RF immunity
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Redundancy
0
Shock
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
Short-circuit protection, outputs available
0
Signal delay
On delay: 20.0 ms
Storage temperature, min
-40 °C
Suitable for safety functions
0
Surge transient immunity
IEC1000-4-5: 2 kV common mode, 1kV differential mode
Time delay at signal exchange
20 ms
Type of electric connection
Screw connection
Type of voltage (input voltage)
AC
Vibration
Operating: 10...500 Hz, 5 G, 0.015 in. maximum, peak-to-peak, 2 hr each axis, Relay ops: 1.5 G
Voltage category
100/120V AC
Weight
209 g
Width
40.4 mm
Bulletin
1762
Series
A
Lifecycle Status
Active Mature