PLC - ControlLogix 5580 Controllersby Allen Bradley

1756-OF8I

ControlLogix 8 Point Analog Output

Analog Output Module, 8 Isolated Points, Current and Voltage (36 Pin)

Specifications

Features
8 Isolated Points, Current and Voltage (36 Pin)
Display
Module Health, In Calibration,Mode, Input, Fault and,Communication Status
Isolation
250V (continuous), reinforced,insulation type, outputs to,backplane. 250V (continuous),basic insulation type, output,to output
Special Features
Per Point Isolation
Analogue inputs configurable
1
Analogue outputs configurable
0
Calibrated accuracy
0.05% @ 25°C (77 °F)
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Current draw
200mA @ 5.1V, Voltage or current mode with 250 Ω loads = 220mA @ 24V, Current mode with 500 Ω loads = 275mA @ 24V, Current mode with 750 Ω loads = 340mA @ 24V, Current mode with 1000 Ω loads = 385mA @ 24V
Data format
IEEE 32-bit floating point
Drive capability
Current output = 0...1000 Ω, Voltage output =>1000 Ω
EFT/B immunity
±4kV @ 5kHz on signal ports
Emissions
IEC 61000-6-4
Enclosure type rating
None (open-style)
ESD immunity
6 kV contact discharges, 8 kV air discharges
Input, current
1
Input, resistance thermometer
0
Input, resistor
0
Inputs
Eight isolated channels - any combination of voltage or current mode
Input signal, configurable
1
Input, thermocouple
0
Input, voltage
1
Isolation voltage
250V (continuous), reinforced insulation type, outputs to backplane, 250V (continuous), basic insulation type, output to output
Module conversion method
R-Ladder DAC, monotonicity with no missing codes
Module error over full temperature range
0.1 %
Module keying
Electronic, software configurable
Module scan time
1 ms minimum
Nonoperating temperature
-40 °C
North American temperature code
T4
Open circuit detection
Current output = Yes
Operating temperature
0 to 60 °C
Output, current
0
Output impedance
46 Ω (Current output)
Output range
-10…10V, 0…10V, 0…5V, 0…20 Ma
Output signal configurable
0
Output, voltage
0
Overvoltage protection
±30V DC (voltage/current)
Power dissipation
Voltage mode: 5.4 W (18.4 BTU/hr), Current mode with 250 Ω loads: 5.4 W (18.4 BTU/hr), Current mode with 500 Ω loads: 5.8 W (19.8 BTU/hr), Current mode with 750 Ω loads: 6.5 W (22.2 BTU/hr), Current mode with 1000 Ω loads: 6.7 W (22.9 BTU/hr)
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Relative humidity
5...95% noncondensing
Resolution
16 bit, ±10.5V (0.32 mV/count), 0...10.5V (0.16 mV/count), 0...5.25V (0.08 mV/count), 0...21 mA (0.32 µA/count)
RTB keying
User-defined mechanical
Settling time
<2 ms to 95% of final value with resistive loads
Shock
Operating: 30 G, Non operating: 50 G
Short circuit detection
Voltage output = Yes
Slot width
1
Suitable for safety functions
0
Surge transient immunity
±2 kV line-earth (CM) on shielded signal ports
Surrounding air temperature, max
60 °C
Thermal dissipation
Voltage mode = 18.4 BTU/hr, Current mode with 250 Ω loads = 18.4 BTU/hr, Current mode with 500 Ω loads = 19.8 BTU/hr, Current mode with 750 Ω loads = 22.2 BTU/hr, Current mode with 1000 Ω loads = 22.9 BTU/hr
Total backplane power
Voltage mode = 6.3 W, Current mode with 250 Ω loads = 6.3 W, Current mode with 500 Ω loads = 7.6 W, Current mode with 750 Ω loads = 9.2 W, Current mode with 1000 Ω loads = 10.2 W
Type of electric connection
Screw-/spring clA connection
Vibration
2 G @ 10...500 Hz
Wire category
2 - on signal ports
Wire size
0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 90 °C (194 °F) or greater, 1.2 mm (3/64 in.) insulation maximum
Bulletin
1756
Series
B
Lifecycle Status
Active