PLC - ControlLogix 5580 Controllersby Allen Bradley

1756-OF8H

ControlLogix 8 Pt A/O I or V HART Module

Analog Output HART - Current/Voltage 8 Pts (20 Pin)

Specifications

Display
Module Health, In Calibration,Mode
Isolation
None between channels (Single,Ended)
Number Of Channels
8
Output Signal
+/- 10.4V, 0-20 mA, 4-20 mA
Special Features
Supports HART Protocol
Analogue inputs configurable
1
Analogue outputs configurable
0
Calibrated accuracy
Voltage: Better than 0.1% of range @ 25 °C (77 °F) with HART disabled, Current: Better than 0.15% of range @ 25 °C (77 °F) with HART disabled
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Data format
Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
EFT/B immunity
±2kV @ 5kHz on signal ports
Emissions
IEC 61000-6-4
Enclosure type rating
None (open-style)
ESD immunity
6 kV contact discharges, 8 kV air discharges
Gain drift with temperature
Voltage: 20 ppm/°C, Current: 35 ppm/°C
Input conversion method
Successive approximation
Input, current
1
Input, resistance thermometer
0
Input, resistor
0
Input signal, configurable
1
Input, thermocouple
0
Input, voltage
1
Isolation voltage
50V (continuous), basic insulation type, output channels to backplane, No isolation between individual output channels type tested at 1500V AC @ 60s
Load reactance
Voltage: 1 µF, Current: 10 µH
Module error
Voltage: 0.15% of range, Current: 0.3% of range
Module HART scan time
Analog: 12 ms, minimum, floating point, HART: typically 1 s per HART channel enabled. Estimate 10 s if all 8 channels have HART enabled, Pass through messages, handheld communicators, sary masters, communication errors, or configuration changes can s
Module keying
Electronic, software configurable
Nonoperating temperature
-40 °C
North American temperature code
T4
Offset drift
100 µV/°C, 200 nA/°C
Open circuit detection time
Current output only (output must be set to <0.1 mA)
Operating temperature
0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Output conversion method
R-Ladder DAC, monotonicity with no missing codes
Output, current
0
Output range
-10…10V, 0…20 mA, 4…20 mA
Outputs
Eight voltage or current, one HART modem per module
Output signal configurable
0
Output, voltage
0
Overvoltage protection
±24V DC
Power dissipation
4.92 W
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Relative humidity
5...95% noncondensing
Resolution
15...16 bit for all ranges
RTB keying
User-defined mechanical
Settling time
Current (no HART): <23 ms to 95% with resistive loads, current (with HART): <37 ms to 95% with resistive loads, voltage: <8.5 ms to 95% with resistive loads
Shock
Operating: 30 G, Non operating: 50 G
Slot width
1
Suitable for safety functions
0
Surge transient immunity
±2kV line-earth (CM) on shielded ports
Surrounding air temperature, max
60 °C
Terminal block torque specifications
1756-TBNH: 1.36 Nm (12 in-lb.)
Thermal dissipation
16.78 BTU/h
Total backplane power
6.54 W
Type of electric connection
Screw-/spring clA connection
Vibration
2 G @ 10...500 Hz
Voltage and current ratings
Backplane: 5.1V DC @ 230mA, 24V DC @ 230mA, Output voltage: -10...+10.4V, Output current: 4...20 mA
Wire category
2 - on signal ports
Wire size
1756-TBNH: Single wire connection: 0.33...2.1 mm² (22...14 AWG) solid or stranded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, 1756-TBNH: Double wire connection: 0.33...1.3 mm² (22...16 AWG) solid or stranded cop
Wire type
Copper
Bulletin
1756
Series
A
Lifecycle Status
Active