PLC - ControlLogix 5580 Controllersby Allen Bradley
1756-IF8IH
ControlLogix 8 Pt A/I HART Isolated
Isolated Analog Input Module - 8-Channel HART
Specifications
- Display
- Module Health, In Calibration,Mode
- Input Signal
- 0-20mA, 4-20mA
- Isolation
- 250V (continuous), reinforced,insulation type, inputs to,backplane
- Number Of Channels
- 8
- Special Features
- Supports HART Protocol
- Analogue inputs configurable
- 1
- Analogue outputs configurable
- 0
- Calibrated accuracy
- 0.15...1.5% of full scale, filter dependent@ 25 °C with HART disabled, 1.5% of full scale with 250 Hz filter @ 25 °C with HART enabled, 0.5% of full scale with 100 Hz filter @ 25 °C with HART enabled, 0.2% of full scale with 50 Hz or 60 Hz filter @ 25 °C
- Common mode noise rejection
- >90 dB @ 50/60 Hz (10 Hz, 15 Hz or 20 Hz filters only)
- Conducted RF immunity
- 10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
- Data format
- 32-bit floating point
- EFT/B immunity
- ±2kV @ 5kHz on signal ports
- Emissions
- IEC 61000-6-4
- Enclosure type rating
- None (open-style)
- ESD immunity
- 6 kV contact discharges, 8 kV air discharges
- Gain drift with temperature
- 20 ppm/°C
- Input conversion method
- Sigma-Delta ADC (24-bit converter)
- Input, current
- 1
- Input impedance
- 250 Ω ±5 Ω
- Input offset drift with temperature
- <=300 µA/°C
- Input overvoltage protection
- 28.8V DC
- Input range
- 0...20 mA (0...20.58 mA), 4...20 mA (3.42...20.58 mA)
- Input, resistance thermometer
- 0
- Input, resistor
- 0
- Inputs
- Eight current inputs
- Input signal, configurable
- 1
- Input, thermocouple
- 0
- Input, voltage
- 1
- Inrush current
- 400mA @ 5V, 450mA @ 24V
- Isolation voltage
- 250V (continuous), Reinforced insulation type, inputs to backplane, Basic insulation type, input to input, and inputs to ground.
- Module error over full temperature range
- 0.3% of range (all filters) with HART disabled
- Module keying
- Electronic, software configurable
- Module scan time
- 18...488 ms (filter dependent) for all channels - analog, minimum
- Nonoperating temperature
- -40 °C
- Normal mode noise rejection
- >90 dB @ 50 Hz and 60 Hz with 10 Hz filter, >74 dB @ 50 Hz and 60 Hz with 15 Hz filter, >33 dB @ 50 Hz and >90 dB @ 60 Hz with 20 Hz filter
- North American temperature code
- T5
- Open circuit detection time
- 5 s (4...20 mA range only)
- Operating temperature
- 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
- Output, current
- 0
- Output signal configurable
- 0
- Output, voltage
- 0
- Power dissipation within module
- 4 W
- Radiated RF immunity
- 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
- Relative humidity
- 5...95% noncondensing
- Resolution
- 16 to 21 bit
- RTB keying
- User-defined mechanical
- Shock
- Operating: 30 G, Non operating: 50 G
- Slot width
- 1
- Suitable for safety functions
- 0
- Surge transient immunity
- ±2 kV line-earth (CM) on shielded signal ports
- Surrounding air temperature, max
- 60 °C
- Terminal block torque specifications
- 1756-TBCH: 0.5 Nm (4.4 in-lb)
- Type of electric connection
- Screw-/spring clA connection
- Typical module HART dynamic variables update time for all channels
- 1 s typical if all channels are HART enabled Pass through messages, handheld communications, sary masters, communication errors, or configuration changes can significantly increase the update time.
- Vibration
- 2 G @ 10...500 Hz
- Voltage and current ratings
- Backplane: 210mA @ 5.1V DC, 110mA @ 24V DC, Input voltage range: 5...30V DC, Input current range: 0...20mA @ 4...20mA
- Wire category
- 2 - on signal ports
- Wire size
- Single wire connection (1756-TBCH): 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm² (22...14 AWG) solid or
- Wire type
- Copper
- Bulletin
- 1756
- Series
- A
- Lifecycle Status
- Active
Request a Quote
Need pricing, availability or more details? We'll get back to you.
Datasheet