PLC - ControlLogix 5580 Controllersby Allen Bradley
1756-IF8I
ControlLogix 8 Point Analog Input
Analog Input Module, 8 Isolated Points, Current, Current Sourcing and Voltage (36 Pin)
Specifications
- Features
- 8 Isolated Points, Current, Current Sourcing and Voltage (36 Pin)
- Display
- Module Health, In Calibration,Mode, Input, Fault and,Communication Status
- Input Signal
- -10GǪ10V, 0GǪ10V, 0GǪ5V, 0G
- Isolation
- 250V (continuous), reinforced,insulation type, inputs to,backplane. 250V (continuous),basic insulation type, input,to input
- Special Features
- Per Point Isolation
- Analogue inputs configurable
- 1
- Analogue outputs configurable
- 0
- Calibrated accuracy
- 0.05% @ 25°C (77 °F)
- Channel bandwidth
- Notch Filter configuration dependent
- Common mode noise rejection
- 120 dB @ 50/60 Hz
- Conducted RF immunity
- 10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
- Current draw
- 200mA @ 5.1V, Voltage/Non-sourcing current mode: 150mA @ 24V, Sourcing current mode: 400mA @ 24V (In sourcing current mode, the channel provides loop power.)
- Data format
- IEEE 32-bit floating point
- EFT/B immunity
- ±4kV @ 5kHz on shielded signal ports
- Emissions
- IEC 61000-6-4
- Enclosure type rating
- None (open-style)
- ESD immunity
- 6 kV contact discharges, 8 kV air discharges
- Input, current
- 1
- Input impedance
- Voltage mode: 1 GΩ approximately (powered), Voltage mode: 7500 Ω approximately (unpowered), Current mode: 125 Ω approximately
- Input range
- -10...10V, 0…10V @ 0...5V, 0...20 mA
- Input, resistance thermometer
- 0
- Input, resistor
- 0
- Inputs
- Eight isolated channels - any combination of voltage or current mode
- Input signal, configurable
- 1
- Input, thermocouple
- 0
- Input, voltage
- 1
- Isolation voltage
- 250V (continuous), reinforced insulation type, inputs to backplane, 250V (continuous), basic insulation type, input to input
- Module conversion method
- Sigma-Delta
- Module error over full temperature range
- 0.1 %
- Module input scan time, min
- 1 ms
- Module keying
- Electronic, software configurable
- Nonoperating temperature
- -40 °C
- Normal mode noise rejection
- 80 dB @ 60 Hz
- North American temperature code
- T4
- Onboard data alarming
- 1
- Open circuit detection time
- 5 s
- Operating temperature
- 0 to 60 °C
- Output, current
- 0
- Output signal configurable
- 0
- Output, voltage
- 0
- Overvoltage protection
- ±30V DC maximum
- Power dissipation
- Voltage mode: 4.6 W (15.7 BTU/hr), Non-sourcing current mode: 5.1 W (17.4 BTU/hr), Sourcing current mode: 7.3 W (24.9 BTU/hr)
- Radiated RF immunity
- 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
- Real-time channel sampling
- 1
- Relative humidity
- 5...95% noncondensing
- Resolution
- 24 bit, ±10.5V (1.49 µV/count), 0...10.5V (1.49 µV/count), 0...5.25V (1.49 µV/count), 0...21 mA (2.99 nA/count)
- RTB keying
- User-defined mechanical
- Scaling to engineering units
- 1
- Settling time
- Notch Filter configuration dependent
- Shock
- Operating: 30 G, Non operating: 50 G
- Slot width
- 1
- Sourcing current, max
- Current limited <45 mA (IN_x/I/SRC to RTN_x)
- Sourcing voltage, max
- 36V DC (open circuit)
- Sourcing voltage, min
- 20V DC
- Suitable for safety functions
- 0
- Surge transient immunity
- ±2 kV line-earth (CM) on shielded signal ports
- Surrounding air temperature, max
- 60 °C
- Thermal dissipation
- Voltage mode: 15.7 BTU/hr, Non-sourcing current mode: 17.4 BTU/hr, Sourcing current mode: 24.9 BTU/hr
- Total backplane power
- Voltage/Non-sourcing current mode: 4.6 W, Sourcing current mode: 10.6 W
- Type of electric connection
- Screw-/spring clA connection
- Vibration
- 2 G @ 10...500 Hz
- Voltage and current ratings
- Backplane: 5.1V DC 200mA @ 24V DC 400 mA, Input voltage: -10V to +10V @ 0V to 10V @ 0V to 5V, Input current: 0 mA to 20 mA, Output current: 0 mA to 20 mA
- Wire category
- 2 - on signal ports
- Wire size
- 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire rated at 90 °C (194 °F), or greater, 1.2 mm (3/64 in.) insulation maximum
- Bulletin
- 1756
- Series
- B
- Lifecycle Status
- Active
Request a Quote
Need pricing, availability or more details? We'll get back to you.
Datasheet
Datasheet not available yet — request it from our team.