Skip to content
PLC - ControlLogix 5580 Controllersby Allen Bradley

1756-IF8I

ControlLogix 8 Point Analog Input

Analog Input Module, 8 Isolated Points, Current, Current Sourcing and Voltage (36 Pin)

Specifications

Features
8 Isolated Points, Current, Current Sourcing and Voltage (36 Pin)
Display
Module Health, In Calibration,Mode, Input, Fault and,Communication Status
Input Signal
-10GǪ10V, 0GǪ10V, 0GǪ5V, 0G
Isolation
250V (continuous), reinforced,insulation type, inputs to,backplane. 250V (continuous),basic insulation type, input,to input
Special Features
Per Point Isolation
Analogue inputs configurable
1
Analogue outputs configurable
0
Calibrated accuracy
0.05% @ 25°C (77 °F)
Channel bandwidth
Notch Filter configuration dependent
Common mode noise rejection
120 dB @ 50/60 Hz
Conducted RF immunity
10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
Current draw
200mA @ 5.1V, Voltage/Non-sourcing current mode: 150mA @ 24V, Sourcing current mode: 400mA @ 24V (In sourcing current mode, the channel provides loop power.)
Data format
IEEE 32-bit floating point
EFT/B immunity
±4kV @ 5kHz on shielded signal ports
Emissions
IEC 61000-6-4
Enclosure type rating
None (open-style)
ESD immunity
6 kV contact discharges, 8 kV air discharges
Input, current
1
Input impedance
Voltage mode: 1 GΩ approximately (powered), Voltage mode: 7500 Ω approximately (unpowered), Current mode: 125 Ω approximately
Input range
-10...10V, 0…10V @ 0...5V, 0...20 mA
Input, resistance thermometer
0
Input, resistor
0
Inputs
Eight isolated channels - any combination of voltage or current mode
Input signal, configurable
1
Input, thermocouple
0
Input, voltage
1
Isolation voltage
250V (continuous), reinforced insulation type, inputs to backplane, 250V (continuous), basic insulation type, input to input
Module conversion method
Sigma-Delta
Module error over full temperature range
0.1 %
Module input scan time, min
1 ms
Module keying
Electronic, software configurable
Nonoperating temperature
-40 °C
Normal mode noise rejection
80 dB @ 60 Hz
North American temperature code
T4
Onboard data alarming
1
Open circuit detection time
5 s
Operating temperature
0 to 60 °C
Output, current
0
Output signal configurable
0
Output, voltage
0
Overvoltage protection
±30V DC maximum
Power dissipation
Voltage mode: 4.6 W (15.7 BTU/hr), Non-sourcing current mode: 5.1 W (17.4 BTU/hr), Sourcing current mode: 7.3 W (24.9 BTU/hr)
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Real-time channel sampling
1
Relative humidity
5...95% noncondensing
Resolution
24 bit, ±10.5V (1.49 µV/count), 0...10.5V (1.49 µV/count), 0...5.25V (1.49 µV/count), 0...21 mA (2.99 nA/count)
RTB keying
User-defined mechanical
Scaling to engineering units
1
Settling time
Notch Filter configuration dependent
Shock
Operating: 30 G, Non operating: 50 G
Slot width
1
Sourcing current, max
Current limited <45 mA (IN_x/I/SRC to RTN_x)
Sourcing voltage, max
36V DC (open circuit)
Sourcing voltage, min
20V DC
Suitable for safety functions
0
Surge transient immunity
±2 kV line-earth (CM) on shielded signal ports
Surrounding air temperature, max
60 °C
Thermal dissipation
Voltage mode: 15.7 BTU/hr, Non-sourcing current mode: 17.4 BTU/hr, Sourcing current mode: 24.9 BTU/hr
Total backplane power
Voltage/Non-sourcing current mode: 4.6 W, Sourcing current mode: 10.6 W
Type of electric connection
Screw-/spring clA connection
Vibration
2 G @ 10...500 Hz
Voltage and current ratings
Backplane: 5.1V DC 200mA @ 24V DC 400 mA, Input voltage: -10V to +10V @ 0V to 10V @ 0V to 5V, Input current: 0 mA to 20 mA, Output current: 0 mA to 20 mA
Wire category
2 - on signal ports
Wire size
0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire rated at 90 °C (194 °F), or greater, 1.2 mm (3/64 in.) insulation maximum
Bulletin
1756
Series
B
Lifecycle Status
Active

Request a Quote

Need pricing, availability or more details? We'll get back to you.

* Required. Please give an email or a phone number.

Prefer WhatsApp? Message us directly

Datasheet

Datasheet not available yet — request it from our team.