PLC - ControlLogix 5580 Controllersby Allen Bradley
1756-IF6I
ControlLogix 6 Point Isolated A/I Module
Isolated Analog Input-Current/Voltage 6 Pts (20Pin)
Discontinued by the manufacturer — contact us for availability, spares or a recommended replacement.
Specifications
- Display
- Module Health, In Calibration,Mode
- Input Signal
- +/- 10V, 0-10.5V, 0-5.25V,0-21mA
- Isolation
- 250 V continuous between,inputs
- Number Of Channels
- 6
- Special Features
- Per Point Isolation
- Analogue inputs configurable
- 1
- Analogue outputs configurable
- 0
- Calibrated accuracy
- Better than 0.1% of range @ 25 °C (77 °F)
- Channel bandwidth
- 15 Hz
- Common mode noise rejection
- 120 dB @ 60 Hz, 100 dB @ 50 Hz
- Conducted RF immunity
- 10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
- Current draw
- 250mA @ 5.1V, 100mA @ 24V
- Data format
- Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
- EFT/B immunity
- ±2kV @ 5kHz on shielded signal ports
- Emissions
- IEC 61000-6-4
- Enclosure type rating
- None (open-style)
- ESD immunity
- 6 kV contact discharges, 8 kV air discharges
- Gain drift with temperature
- Voltage: 35 ppm/°C, 80 ppm/°C maximum, Current: 45 ppm/°C, 90 ppm/°C maximum
- Input, current
- 1
- Input impedance
- Voltage: >10 MΩ, Current: 249 Ω
- Input range
- ±10.5V @ 0...10.5V, 0...5.25V @ 0...21mA
- Input, resistance thermometer
- 0
- Input, resistor
- 0
- Inputs
- 6 individually isolated
- Input signal, configurable
- 1
- Input, thermocouple
- 0
- Input, voltage
- 1
- Isolation voltage
- 250V (continuous), basic insulation type, input channels-to-backplane, and input channel-to-channel Routine tested at 1350V AC @ 2s
- Module conversion method
- Sigma-Delta
- Module error
- 0.54% of range
- Module input scan time, min
- 25 ms minimum - floating point, 10 ms minimum - integer
- Module keying
- Electronic, software configurable
- Nonoperating temperature
- -40 °C
- Normal mode noise rejection
- 60 dB @ 60 Hz
- North American temperature code
- T4A
- Offset drift
- 2 µV/°C
- Onboard data alarming
- 1
- Open circuit detection time
- Positive full scale reading within 5 s
- Operating temperature
- 0 °C
- Output, current
- 0
- Output signal configurable
- 0
- Output, voltage
- 0
- Overvoltage protection
- Voltage: 120V AC/DC maximum, Current: 8V AC/DC (with onboard current resistor), maximum
- Power dissipation
- Voltage: 3.7 W, maximum, Current: 4.3 W, maximum
- Radiated RF immunity
- 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
- Real-time channel sampling
- 1
- Relative humidity
- 5...95% noncondensing
- Resolution
- 16 bit, 10.5V: 343 µV/bit, 0...10.5V: 171 µV/bit, 0...5.25V: 86 µV/bit, 0...21 mA: 0.34 µA/bit
- RTB keying
- User-defined mechanical
- Scaling to engineering units
- 1
- Settling time
- <80 ms to 5% of full scale
- Shock
- Operating: 30 G, Nonoperating: 30 G
- Slot width
- 1
- Suitable for safety functions
- 0
- Surge transient immunity
- ±2 kV line-earth (CM) on shielded signal ports
- Surrounding air temperature, max
- 60 °C
- Thermal dissipation
- Voltage: 12.62 BTU/hr, Current: 14.32 BTU/hr
- Total backplane power
- 3.7 W
- Type of electric connection
- Screw-/spring clA connection
- Vibration
- 2 G @ 10...500 Hz
- Wire category
- Category: 2
- Bulletin
- 1756
- Series
- A
- Lifecycle Status
- Discontinued
Request a Quote
Need pricing, availability or more details? We'll get back to you.
Datasheet
Datasheet not available yet — request it from our team.