Specifications

Conducted RF immunity
10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
Count range, max
2, 147, 483, 647
Current draw
300mA @ 5.1V, 16mA @ 24V
Digital inputs configurable
1
Digital outputs configurable
0
EFT/B immunity
±4kV @ 5kHz on unshielded output and power ports, ±4kV @ 5kHz on shielded input ports
Emissions
IEC 61000-6-4
Enclosure type
None (open-style)
ESD immunity
6 kV contact discharges, 8 kV air discharges
Filtering (inputs F0 & F1)
Firmware selectable: high-speed 100 kHz or low-pass filter for frequencies <70 Hz
Flowmeter input impedance
5 kΩ ±30% resistive
Flowmeter input voltage
±30V, selectable input thresholds of 50mV @ 1.3V and 4V: ±30V peak unterminated open circuit voltage, magnetic pickup, TTL compatible, input voltage >1.3V DC is Logic 1 and -0.7...1.3V DC is Logic 0, 12...24V DC powered preA output, 4V DC threshold
Frequency
Resolution: 0.0005 Hz
Gate input on-state current, min
4 mA
Gate input on-state current, nom
15 mA
Gate input voltage range
5V ops: 4.5...5.5V DC @ 12/24V ops: 10...26.4V DC
High resolution, max
100 khz
Input frequency, max
100 kHz @ flowm inputs (overrange occurs at 100 kHz)
Input sampling period
User selectable
Inputs
Two flowm (F) inputs used for all modes, Two gate inputs used in Totalizer mode for prover/store count, 4 (2 per channel)
Isolation voltage
250V (continuous), reinforced insulation type, I/O-to-backplane, 250V (continuous), basic insulation type, I/O group-to-group
Mechanical filter debouncing (Z0 & Z1 Inputs)
Software selectable
Module keying
Electronic, software configurable
Nonoperating temperature
-40 °C
North American temperature code
T4
Off-state leakage current, max
<300 µA @ 31.2V DC
On-state voltage drop, max
0.6 Ω x current
Operating temperature
0 to 60 °C
Output control
Any number of outputs is assignable to any of two flowm channels each output can have 2 “turn-on” and “turn-off” preset values
Output current per point
1 @ 10...31.2V DC @ 20mA @ 4.5...5.5V DC
Output reverse polarity protection
Yes (if wired incorrectly, module outputs can be permanently disabled.)
Outputs
2 current sourcing
Output short circuit protection
Electronic (no indication of fault. remove overload and toggle output on/off to restore.)
Output switching time
<50 µs turn on, <300 µs turn off, Outputs triggered by Total, all other “turn-on” and “turn-off” times <1 ms
Output type
IEC 1 A 24V DC
Output voltage range, nom
5V ops: 4.5...5.5V DC @ 3...20mA load per point, 12/24V ops: 10...31.2V DC @ 40mA...1 A load per point
Output voltage source
Customer supplied
Overload current
Electronic (<4 A)
Power dissipation, max
6 W @ 60 °C (140 °F)
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Redundancy
0
Relative humidity
5...95% noncondensing
Reverse polarity protection
Outputs only
RTB keying
User-defined mechanical
Shock
Operating: 30 G, Non operating: 50 G
Short-circuit protection, outputs available
0
Slot width
1
Suitable for safety functions
0
Surge current
2 A @ 50 ms, repeatable every 2s
Surge transient immunity
±1 kV line-line (DM) and ±2 kV line-earth (CM) on unshielded output and power ports, ±2 kV line-earth (CM) on shielded input ports
Surrounding air temperature, max
60 °C
Thermal dissipation
20.4 btu/h
Total backplane power
1.7 W
Totalizer fill and prover
1
Type of electric connection
Screw connection
Vibration
2 G @ 10...500 Hz
Voltage type of supply voltage
DC
Wire category
2 on signal ports, 1 on power ports
Bulletin
1756
Series
B
Lifecycle Status
Active